Fittings and other

PVC Adaptor

 

Adapters PVC manufactured in accordance with organization number 96365-1910 ST-TOO-03-2011. Adapters are used to connect PVC casing pipes of different
diameters to each other and with the filter casing column, as well as to connect the pipelines transporting water for drinking water, at temperatures from 0 ° C to
45 ° C, and other liquid and gaseous substances, the which is chemically resistant PVC.

 

Basic parameters and dimensions

 


diameter

adapters, mm

The thickness of the wall adapter, mm

Adapter length, mm

Rated

Maximum deviation

Rated

Maximum deviation

195х90

14/8

+0,8

400-600

+5,0

195х140

14/10

+0,8

400-600

+5,0

140х90

10/8

+0,7

400-600

+5,0

140х110

10/8,1

+0,7

400-600

+5,0

90х113

8/10

+0,7

400-600

+5,0

113х90

10/8

+0,7

400-600

+5,0

195х113

14/10

+0,8

400-600

+5,0

 

Adapter HDPE

 

Adapters of the high-density polyethylene produced by the Standard Organization № CT 96365-1910-LLP-05-2011. Adapters are used to connect the HDPE casing
pipes of different diameters to each other and with the filter casing column, as well as to connect the pipelines to transport water for drinking water and other
liquids, acid, gaseous matter, which is chemically resistant polyethylene.

 

Basic parameters and dimensions

 

Dimensions, mm

Wall thickness, mm

Length, mm

Rated

Maximum

deviation

Rated

Maximum

deviation

adapter HDPE 90 90вн.×110н.

18

+1,0

350-400

+5,0

adapter HDPE 90110вн.×90н

18

+1,0

350-400

+5,0

adapter HDPE 90 160вн.×90вн.

18/20

+1,3

400-450

+5,0

adapter HDPE 90 160н.×110вн.

18/18

+1,2

350-400

+5,0

adapter HDPE 90 160вн.×110н.

18/18

+1,3

400-450

+5,0

adapter HDPE 90 210вн.×110н.

18/18

+1,5

550-600

+5,0

adapter HDPE 90 210н.×110вн.

18/18

+1,5

550-600

+5,0

adapter HDPE 90 210вн.×195н.

18

+1,0

400-450

+5,0

 

Frame-disc filters

 

Frame-disc filters (hereinafter - the KDF filters are available in Standard, the organization number ST-96365 1910-LLP-04-2011. KDF filters are a set of disks made
of polymeric material collected on the perforated PVC frame (trumpet) and forming a transverse annular gap conic section .

Filters are designed to be used:

wells-in process for in-situ leaching (PSV) technology to filter the sulfuric acid solutions with concentrations up to 30 mg/dm3 in their fence and discharge in the
producing horizons represented inequigranular sands;

vodoosusheniya-in systems and land reclamation;

in-water intake wells for drinking and household water supply;

-pre-treatment with water and sewage;

at the device drain-sand filters.

 

Basic parameters and dimensions

 

Designation

of the filter

Inner

diameter,

mm

Outer

diameter,

mm

Length

of

section,

mm

The gap

width,

mm

The

length

of the

working

part, mm

The number of

diametrical slots

on the ring, pcs

Duty cycle of the

filter,% not less

Number of disks

1 m of the

working part of

the filter unit.

KDF 118х90

74

118

2000

0,5
0,8
1,0
1,2
1,5

1800

120

15
23
28
33
40

116-135
112-130
110-127
107-125
105-123

KDF 91х63

51

91

2000

0,5
0,8
1,0
1,2
1,5

1800

92

13
20
25
29
36

116
112
110
107
105

KDF 186х140

120

186

2000

0,5
0,8
1,0
1,2
1,5

1800

188

13
20
25
29
36

116
112
110
107
105

 

Filters slotted

 

Filters slot (hereinafter - the filters) manufactured in accordance with organization number ST-96365 1910-LLP-07-2011. Filters made of polymeric materials are
cut by a tube having a slit of different widths along the circumference.

Filters are made of different diameters and are intended for use:

wells-in process at PSV (in-situ leaching) technology to filter sulfuric acid solutions with concentrations up to 30 mg/dm3 in their fence and discharge in the
producing horizons represented inequigranular sands;

vodoosusheniya-in systems and land reclamation;

in-water intake wells for drinking and household water supply;

-pre-treatment with water and sewage;

at the device drain-sand filters.

 

Basic parameters and dimensions of filters

 

Designation of

the filter

Inner

diameter,

mm

Outer

diameter,

mm

Current

nominal length,

mm

The

distance

between

the slits,

mm

The number

of diametrical

slots in the

series, ea.

The nominal

width of the

gap, mm

Duty cycle

of the

filter,% not

less

Number of

rows of slots

for 1 m of the

working of the

filter unit.

CHF 63

51

63

2000; 3000; 4000; 5000; 6000;

5,0

3

0,5

5,6

182

0,7

7,6

175

1,0

10,4

167

1,2

12,1

161

1,5

14,4

154

1,8

16,5

147

2,0

17,8

143

CHF 90

74

90

2000; 3000; 4000; 5000; 6000;

5,0

3

0,5

6,7

182

0,7

9,1

175

1,0

12,3

167

1,2

14,3

161

1,5

17,1

154

1,8

19,6

147

2,0

21,2

143

CHF 110

94

110

2000; 3000; 4000; 5000; 6000;

5,0

3

0,5

7,2

182

0,7

9,7

175

1,0

13,3

167

1,2

15,4

161

1,5

18,4

154

1,8

21,1

147

2,0

22,7

143

CHF 140

120

140

2000; 3000; 4000; 5000; 6000;

5,0

4

0,5

7,1

182

0,7

9,6

175

1,0

13,1

167

1,2

15,2

161

1,5

18,2

154

1,8

20,8

147

2,0

22,5

143

 

Covers PVC casing

 

Covers PVC casing annular cross-section (hereinafter - the cover) are available on the organization of the Standard number ST-96365 1910-LLP-08-2011. The covers
are designed to close the top and bottom of the casing to eliminate the ingress of soil and foreign material in the production casing. Also, for the detention of the
barrel column productive mass coming through the perforations in the casing and when the time for conservation or technological necessity.

 

Basic parameters and dimensions of closures

 

Наименования изделий

Wall thickness, mm

The average outer diameter, mm

Length, mm

Rated

Maximum

deviation

Rated

Maximum

deviation

Rated

Maximum

deviation

from the stub

by thread

from the stub

by thread

Cover the bottom of PVC-90

8

+0,6

90

100

+0,3

150

±2,5

Cover the top of PVC-90

8

+0,6

90

90

+0,3

150

±2,5

Cover the bottom of PVC-113

10

+0,7

113

128

+0,3

150

±2,5

Cover the top of PVC-113

10

+0,7

113

113

+0,3

150

±2,5

Cover the top of PVC-195

14

+0,9

195

195

+0,4

150

±2,5

 

Sump plug made of polyethylene (HDPE)

 

Cork HDPE tank manufactured in accordance with organization number 96365-1910 ST-TOO-05-2011. Cork is designed to seal the tank (cap) tank leaching wells
operating in the pressure and pressure conditions.

 

Basic parameters and dimensions

 

Dimensions, mm

Wall thickness, mm

Length, mm

Rated

Maximum

deviation

Rated

Maximum

deviation

sump plug PND 110×18, 90 int.

18

+1,0

200-250

+5,0

sump plug PND 110×18, 110 int.

18

+1,0

200-250

+5,0